Dynacom Inc.
Industrial Filtration   - Since 1978
  • mistbuster800

    Filtration Stages:

    1st Stage: 2" baffled inertial impinger
    2nd Stage: 2" aluminum mesh impinger
    3rd Stage: AQE Advantage (Long Life) Electronic Cell
    4th Stage: MistBuster (High-Efficiency) Cell
    5th Stage: Optional MistBuster (High-Efficiency) Cell
    6th Stage: Optional HEPA filter 99.97% efficiency, ESF Filter, or Carbon Module

    Principles of Operation:

    Polluted air is drawn through the first stage mechanical mist impingers. These impingers are designed to remove the larger mist droplets and particles. The remaining submicron particles are removed in the second and third stage electrostatic precipitator (ESP) sections.

    To optimize efficiency, an aluminum post-filter entraps particles which may have been agglomerated on the cell plates. Clean air is then returned to the room.

  • mistbuster_brochure

    The MistBuster® 500 is a self-contained mist removal system designed to capture mist and smoke from metal working applications in industry. The MistBuster® can be direct mounted to machine tools or ducted using optional plenum and flex hose. The MistBuster® is the superior alternative to conventional centrifugal and media-type systems.

    Filtration Stages:
    1st Stage: 2” baffled inertial impinger
    2nd Stage: 2” aluminum mesh impinger
    3rd Stage: DuroClean (Long Life) Electronic Cell
    4th Stage: Optional HEPA filter 99.97% efficiency, ESF Filter, or Carbon Module

    Principles of Operation:

    Polluted air is drawn through the first stage mechanical mist impingers. These impingers are designed to remove the larger mist droplets and particles. The remaining sub-micron mist droplets and particles are removed in the second stage through the process of electrostatic precipitation (ESP). The ESP provides an intense electrical charge on the remaining contaminants through the ionizing field. The collection cell, which works much like a magnet, attracts and removes the charged mist droplets from the air stream. To optimize efficiency, an aluminum post- filter entraps particles, which may have been agglomerated on the cell plates. Clean air is then returned to the room.

  • MistBuster 2000

    Filtration Stages:

    1st Stage: 4" aluminum mesh impingement
    2nd Stage: AQE Advantage (Long Life) Electronic Cell x 2
    3rd Stage: MistBuster (High- Efficiency) Cell x 2
    4th Stage: Optional MistBuster (High-Efficiency) Cell x 2
    5th Stage: Optional HEPA filter 99.97% efficiency, ESF Filter, or Carbon Module

    Principles of Operation:

    Polluted air is drawn through the first stage mechanical mist impingers. These impingers are designed to remove thelarger mist droplets and particles. The remaining sub-micron mist droplets and particles are removed in the second stage through the process of electrostatic precipitation (ESP). The ESP provides an intense electrical charge on the remaining contaminants through the ionizing field. Two primary collection cells, laced side-by-side, work much like magnets attracting and removing charged mist droplets from the airstream. A third stage, also comprised of electrostatic cells, collects any fine mist particles that may have migrated through, increasing the overall efficiency up to 99.9%! Aluminum post-filters entrap particles, which may have been agglomerated on the cell plates.

    Clean air is then returned to the room.