Dynacom Inc.
Industrial Filtration   - Since 1978

Call (440) 543-1900 or emial info@dynacomonline.com for a MistBuster Quick Quote to be emailed to you ASAP!!!!

Need multiple units? Let us know and we can potentially provide bulk discounts!!!!

Unit of Measure

DIMENSIONS

N/A 23.5” H x 13.5” W x 25” L

INLET OPENING

N/A 16.62” x 9.08”

WEIGHT

N/A 102 lbs. shipping weight 91 lbs. installed

CABINET

N/A 16-gauge welded steel cabinet with powder coated enamel finish

AIRFLOW

N/A Variable to 850 cfm

EFFICIENCY

N/A Up to 99.9% efficiency on submicron particles.

FILTRATION

N/A 1st Stage: 4” aluminum mist impingers 2nd & 3rd Stage: High efficiency ESP filters 4th Stage: 1” aluminum mesh 5th Stage: Optional HEPA or carbon

POWER SUPPLY

N/A Two self-regulating, dual voltage, solid statepower supplies, one for each ESP cell.

MOTORIZED IMPELLER

N/A Backward curved, vibration-free, direct driverated 850 CFM at .7” H2O.

POWER

N/A 115 Vac, 60 Hz, single phase, 2 amps 240 Vac, 60 Hz, single phase, 1 amp

POWER CORD

N/A Ten-foot power cord with standard molded plug

SOUND LEVELS

N/A 70 dBA at 6’ (at max airflow) 74 dBA at 3’ (at max airflow)

N/A PRINCIPLES OF OPERATION:

Polluted air is drawn through the first stage mechanical mistimpingers. These impingers are designed to remove thelarger mist droplets and particles. The remaining submicronparticles are removed in the second and third stageelectrostatic precipitator (ESP) sections.

To optimize efficiency, an aluminum post-filter entrapsparticles which may have been agglomerated on the cellplates. Clean air is then returned to the room.

STANDARD FEATURES:
  • Motor starter and control circuitry included.
  • Infinitely variable motor speed controller
  • Dual power supplies, one for each stageESP provides increased collectionefficiency as well as redundancy.
  • Exclusive coolant selector switch
  • 10-foot cord with molded plug
  • 3-year parts warranty
OPTIONAL ACCESSORIES:
  • Source capture plenum
  • Direct mount kits for many popularmachine tools.
  • Add on HEPA, ESF or carbon modules.
  • Pedestal mounting kit
  • Wall mounting kit
  • Machine mount stand
  • Ceiling mount kit
  • Optional wall mount variable speedcontroller
  • Dacron prefilter